Comparative assessment of quadratic programming solvers for neutron spectrum unfolding

22 Jun 2026, 14:30
15m
Conference Hall (MLIT)

Conference Hall

MLIT

Methods and numerical algorithms in high-energy physics Mathematical methods and tools for modeling complex physical systems

Speaker

Константин Чижов (Radiation safety department)

Description

This paper presents an approach for neutron spectrum unfolding formulated as a quadratic programming problem. The relationship between measurements obtained with a Bonner multisphere spectrometer (BSS) and the neutron spectrum is described by a system of Fredholm integral equations of the first kind, the discretization of which yields an ill-posed system of linear algebraic equations. To obtain a stable solution, Tikhonov regularization is used. In our work the inverse problem is transformed into a constrained optimization problem with a non-negativity constraint on the spectrum. A comparative analysis is conducted on solvers integrated into the Python environment via the qpsolvers and cvxpy packages: ECOS, Clarabel, SCIP, SCS, SDPA, CPLEX, HiGHS, PROXQP, OSQP, and QUADPROD. An interface to the Cosmo solver from Julia language was also implemented. The optimal regularization parameter was selected using generalized cross-validation as implemented in the pytikhonov package. The methods are validated using an ensemble of 20 spectra from the IAEA Compendium, simulated via Monte Carlo transport code, including reference spectra such as 252Cf and 241AmBe, as well as realistic workplace neutron fields. Unfolding quality is quantitatively assessed using a suite of metrics: mean square error (MSE), Wasserstein distance, coefficient of determination (R2), cosine similarity, and an integral metric—the relative uncertainty in effective dose rate estimation. The study was done for a BSS with polyethylene spheres with diameters of 3, 4, 5, 6, 8, 9, 12, and 18 inches, supplemented by spheres with lead inserts of 9, 12, and 18 inches in diameter to enhance sensitivity above 20 MeV. The results demonstrate that solver selection significantly influences solution quality. Based on a composite evaluation of the metrics, the SCS solver yields the best overall performance. The relative error in effective dose rate estimation across solvers ranges from 0.7 to 1%, with Cosmo achieving the highest accuracy. All methods exhibit comparable performance in terms of R2 (0.69–0.71) and cosine similarity (0.90–0.91). Notably, unfolding methods are shown to introduce artifacts manifesting as spurious peaks in the energy range above 20 MeV. In the context of radiation safety, such artifacts risk being misinterpreted as indicative of shielding deficiencies or the presence of non-existent high-energy radiation. Furthermore, configurations relying on BSS spheres with reduced sensitivity in the high-energy region (i.e., without lead inserts) exacerbate the prevalence of such spurious peaks. The proposed algorithms are implemented in bssunfold python package. It can be used to improve dose assessment in high-energy neutron fields.

Authors

Stepan Shirkov (Russia) Алексей Чижов (Joint Institute for Nuclear Research) Константин Чижов (Radiation safety department)

Presentation materials