MiniSPD - cosmic muon testing facility

11 Oct 2021, 11:00
15m
https://jinr.webex.com/jinr/j.php?MTID=meb12aaca113321b28f8c123868a1ac0f

https://jinr.webex.com/jinr/j.php?MTID=meb12aaca113321b28f8c123868a1ac0f

Oral High Energy Physics High energy physics

Speaker

Ysmaiyl Kambar (JINR)

Description

MiniSPD is setup for cosmic muon tests. MiniSPD includes most of types of detectors that will be used in SPD detector . Detectors and readout electronics for the NA64 experiment were used as the main test object. The MiniSPD setup includes a scintillator trigger system, straw, silicon and GEM trackers, an electromagnetic calorimeter, and a lead filter to remove low energy components of cosmic rays. Also, the main goal of MiniSPD was to measure such important parameters of prototypes of detectors as spatial and time resolution, efficiency, drift characteristics, gas gain, data acquisition parameters, implementation of slow control and features of online monitoring systems. The data from the stand can be used for further preparation of the infrastructure of the beam zone, also to study of such systems as power supply, climate control systems, etc.

Primary authors

Ysmaiyl Kambar (JINR) Kirill Salamatin Temur Enik (Russia) Evgenii Martovitsky

Presentation materials

There are no materials yet.