This report presents the development and testing results of two Micromegas prototype detectors designed for the SPD experiment, conducted at the CERN PS/T9 beamline. The study focuses on optimizing detector performance by evaluating the impact of pillar geometry, strip pitch, and the resistance of the protective DLC (Diamond-Like Carbon) layer using multi-channel electronics. Experimental results demonstrate an intrinsic detection efficiency of approximately 99% and a spatial resolution of about 80 µm. A comparative analysis was performed to assess the influence of design parameters—specifically two strip pitch options and two distinct DLC surface resistance values—on noise levels and cluster size. These findings are instrumental in determining the optimal detector configuration for the final assembly of the SPD tracker.